CLEARING A JAMMED FASTENER
Disconnect tool from air supply.
1. Open magazine and remove remaining fasteners (Fig. 28 and Fig. 29).
Remove fasteners from tool before opening the
fastener guide plate. Fasteners are under pressure and may shoot
out of magazine which could cause injury.
2. Open the quick release latch and the fastener guide plate (Fig. 30).
3. Remove the jammed fastener (Fig. 31).
4. Close the fastener guide plate, and the quick release latch.
Fig. 29
Fig. 28
Fig. 31
Fig. 30