Delta Digital timer Manuale Utente Pagina 34

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 74
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 33
Astronomical Time Switch in 35mm size
• Latitude/Longitude precise to the minute with time zone
• Sunrise/Sunset or Twilight rise/set trigger modes
• Ease of programming & navigation
• DST, Offset, OFF Hours, Weekly OFF features
• 12/24 Hour display format
• 6 years battery reserve
• Easy Manual Override
• Ideal for Outdoor & Street lighting applications
Cat. No.
T2DDT7
Supply Voltage & Frequency
Number of Modes & Description
110 - 240 VAC, -20 % , 50 / 60 Hz+10%
T2DDT7
110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)
Description
Cat. No.
Parameters
Power Consumption (Max.)
Programming
Minimum Switching Time
Clock Accuracy
Power Reserve from Factory
Switching Contacts
Contact Rating
Electrical Life
± 2 s/day max. over the Operating Temperature range
Resistive: - 16A (For 'NO') & 5A (For 'NC') @ 240 VAC / 24 VDC
4
3x10
6 VA
1min
Based on:
1) Latitude/Longitude precise to the minute with time-zone
2) Option for both Sunrise/Sunset & Twilight rise/set trigger
3) DST feature (1 Hour) with indication on screen
4) Weekly OFF
5) Offset for rise/set
6) OFF-Hours
Operating
Storage Temperature
Temperature
-10°C to + 55°C
-10°C to + 60°C
6 Years
1 C/O (SPDT)
Inductive (cos ø = 0.6) :- 6 A @ 250 VAC
Incandescent Lamp: - 1000 W
ORDERING INFORMATION
LED Indication
Enclosure
Dimension (W x H x D)
Weight
(in mm)
(unpacked)
Mounting
Certification
Applications
Degree of Protection
F a e Re r Vl m ta dant UL94 0
36 65 90 X X
1 g 10
Ba D N r lse / I ai
s fo sIP 20 for Terminal , IP 40 r Enclo ure
t l o , i usStree ighting applicati ns in cities ndustrial townships, university camp es
ht n c l t a .Lig ing automatio in sports omp ex, ho els, p rks & other outdoor applications
Re Re a ONd l y
EMI/ EMC
Radio Interference Suppression
ESD
Electrical Fast Transients
Surges
Voltage Dips & Interruptions
mode setting (Manual override)
FUNCTIONS OF KEYS:
ESC : Previous Menu / Undo Change
: Menu scroll up / Increase parameter value / View Output OFF time in standby mode
: Menu scroll down / Decrease parameter value / View Output ON time in standby mode
OK : Enter programming mode / selecting a particular parameter to edit / applying & confirming changes
RST : Resets clock & other programs & settings to default
MAN : For
: Exit programming mode / 12 or 24 Hour clock mode selection in standby mode
Contact Material
Mechanical Life
Ag Alloy
3
50 X 10
Three
AUTO
• ON AUTO
AUTO OFF
As per user defined program settings
Manual ON up to next auto event
Manual OFF up to next auto event
-
-
-
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.11 A
LCD Display
3 Lines Text LCD
RoHS
Compliant
Astronomical Time Switch
TM
CISPR 14-1
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-11
Ed. 5.0 (2005-11) Class B
Ed. 1.2 (2001-04) Level II
Ed. 2.0 (2004-07) Level IV
Ed. 2.0 (2005-11) Level IV
Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)
MAN
ESC
OK
RST
32