Glitch Trigger
Glitch triggers upon finding a fixed pulse-width time or time range.
On the Trigger dialog, select Smart trigger type, then Glitch to display the controls.
1. Choose the Source input line.
2. Choose the Polarity on which to trigger.
3. Choose the Logic Family that marks the High-Low logic threshold. To enter a custom
threshold, choose Logic Family User Defined and enter the voltage Level.
NOTE: The Logic Family will default to any Logic Setup associated with that line in a
previous digital group setup.
4. Use Glitch Condition is settings to create an expression describing the glitch width.
This may be:
l Any width Less Than an Upper Value.
l Any width In Range of values marked by the specified Upper Value and Lower
Value.