Sommario

Pagina 1 - The heart of your PV system

Version: AP, Language: enAPSolar inverters for Asia-Pacific from Delta - The heart of your PV system

Pagina 2

8SOLIVIA 3.3 AP G3 TRSolar Inverter SOLIVIA 3.3 AP G3 TRSOLIVIA 3.3 TR - the third generation of solar inverters from Delta - offers exciting and inno

Pagina 3 - Product overview

9Technical data SOLIVIA 3.3 AP G3 TRINPUT (DC) AUSTRALIA CHINA INDIA KOREA TAIWANMax. recommended PV power 4000 WPNominal power 3630 WVoltage range 12

Pagina 4

10SOLIVIA 5.0 AP G3 TRSolar Inverter SOLIVIA 5.0 AP G3 TRThe latest high frequency technology used in the SOLIVIA 5.0 TR solar inverters for the Asian

Pagina 5

11Technical data SOLIVIA 5.0 AP G3 TRINPUT (DC) AUSTRALIA CHINA INDIA THAILAND PEAMax. recommended PV power 6000 WPNominal power 5500 WVoltage range 1

Pagina 6 - SOLIVIA 2.5 AP G3 TR

12SOLIVIA - Modular central invertersState-of-the-art touch-screen displayThe user-friendly menu navigation via the integrated touch-screen display ma

Pagina 7

13Within the central inverter product line, Delta offers two types of cabinet sizes: The smaller cabinet systems, SOLIVIA CS, provide maximum fl exibil

Pagina 8 - SOLIVIA 3.0 AP G3 TR

14SOLIVIA CS 44, SOLIVIA CS 55 & SOLIVIA CS 66Technical data SOLIVIA CS AP G3INPUT (DC) CS 44 CS 55 CS 66Max. recommended PV power 54 kWP67 kWP80

Pagina 9

15Technical data SOLIVIA CM AP G3INPUT (DC) CM 77 CM 88 CM 100Max. recommended PV power 94 kWP106 kWP120 kWPNominal power 82 kW 93 kW 105 kWVoltage ra

Pagina 10 - SOLIVIA 3.3 AP G3 TR

16SOLIVIA - Block inverters for Asia-PacificSOLIVIA CL 250 AP G1 MSBlock Inverter CL 250 AP G1 MSDelta’s SOLIVIA CL 250 AP G1 MS is particularly suita

Pagina 11

17Easy maintenanceThe easily accessible components in the cen-tral inverter cabinet make maintenance very easy. If a fault should occur, the diagnosti

Pagina 12 - SOLIVIA 5.0 AP G3 TR

ContentAbout us 1Product overview 1SOLIVIA - Solar inverters for Asia-Pacific 2 String inverters with transformer 2Modular central inverters 12Bl

Pagina 13

18SOLIVIA MonitorThe SOLIVIA GW Gateway and SOLIVIA Monitor web portal allow continuous monitoring of your PV system from anywhere that you have inter

Pagina 14

19Simple and secure data reportingReal-time performance data is gathered from the inverters, sent over the internet, and pre-sented on your computer o

Pagina 15

20SOLIVIA MonitorThe SOLIVIA Monitor is ideal for monitoring residential PV solar systems due to it’s user-friendly interface that provides a quick ov

Pagina 16

21LANGUAGESAvailable languagesEnglish, French, Spanish, Italian, German, Czech, Portugese, Slovak, Dutch, Simplified Chinese, Traditional Chinese, Kor

Pagina 17

22Grounding kitPART NUMBER DELTAGROUNDING KITEOE99000275Kit for grounding Delta’s Asian-Pacific solar inverters SOLIVIA 2.5 TR, SOLIVIA 3.0 TR, SOLIVI

Pagina 18 - SOLIVIA CL 250 AP G1 MS

23PART NUMBER DELTACONNECTION CABLE3081129500Connection cable from Delta solar inverter to WEB’Logger from Meteocontrol: - Assembled outdoor cable wit

Pagina 19

24PART NUMBER DELTAPLUG CONNECTORS Female cable coupler as individual part (including insulating part)Type: PV-KBT4/2,5I-UR; Ø range of cable gland: 3

Pagina 21 - Here is how it works:

www.solar-inverter.com24 November 2011 - All information and specications are subject to change without notice.EUROPEDelta Energy Systems (Germany) G

Pagina 22

1About usProduct overviewCOUNTRY SOLIVIA 2.5 AP G3 TR SOLIVIA 3.0 AP G3 TR SOLIVIA 3.3 AP G3 TR SOLIVIA 5.0 AP G3 TRAustraliaChinaIndiaKoreaTaiwanThai

Pagina 23

2SOLIVIA - Solar inverters for Asia-PacificString inverers with transformerDelta, with over 70 years of power electronics experience, presents high ef

Pagina 24 - Service Software Kit

3SOLIVIA - Solar inverters for Asia-PacificString inverers with transformerReference installation: World Stadium Khaosiung - Taiwan:1 MW nominal outpu

Pagina 25 - Connection cables - Harting

4SOLIVIA 2.5 AP G3 TRSolar Inverter SOLIVIA 2.5 AP G3 TRThe SOLIVIA 2.5 TR solar inverters for the Asian-Paci c region are highly ef cient and relia

Pagina 26

5Technical data SOLIVIA 2.5 AP G3 TRINPUT (DC) AUSTRALIA CHINA INDIA KOREA TAIWANMax. recommended PV power 3100 WPNominal power 2750 WVoltage range 12

Pagina 27

6SOLIVIA 3.0 AP G3 TRSolar Inverter SOLIVIA 3.0 AP G3 TRThe new SOLIVIA 3.0 TR solar inverters has a nominal output power of 3000 W. The SOLIVIA strin

Pagina 28

7Technical data SOLIVIA 3.0 AP G3 TRINPUT (DC) AUSTRALIA CHINA INDIA KOREA TAIWANMax. recommended PV power 3650 WPNominal power 3300 WVoltage range 12